7 Alarms and messages
MIRUS Controller, SW 2.03.02, Additional Information Master (en-GB)
7-15
No.
Message
(in order of
testing)
Set condition
Required user
action
Device action
A05
Thank you! Power
up test will now
proceed
automatically.
Fill port flap is
closed.
None or turn off
MIRUS Controller
via turn off button.
Performs Power
up test or turn
OFF sequence
after user
selection.
A06
The Fill port flap is
open.
Please close...
The Fill port flap is
open for > 4 min
Close Fill port flap
or turn off MIRUS
Controller via turn
off button.
Waits for closed
Fill port flap or
performs turn OFF
sequence after
user selection.
A07
Internal battery not
fully charged.
Limited power
supply capability.
To continue
please confirm.
Internal UPS
battery low.
Confirm low
battery capacity or
recharge battery
while system is
supplied with line
power prior to
operation or turn
off MIRUS
Controller via turn
off button.
Charges UPS
battery (as usual)
or performs turn
OFF sequence
after user
selection.
A08
Internal battery
capacity too low.
Operation is
prohibited.
Wait for
recharging to an
appropriate level.
Internal UPS
battery low.
Wait until battery
charging level has
reached status of
A07. System then
automatically
switches to A07 or
turn off MIRUS
Controller via turn
off button.
Charges UPS
battery (as usual)
or performs turn
OFF sequence
after user
selection.
A09
Internal battery
(UPS) failure.
Operation is
prohibited.
To turn off device
please confirm.
UPS battery
defective.
Confirm to turn off
MIRUS Controller.
Then disconnect
MIRUS Controller
from AC and
contact your
service
organisation.
Performs turn OFF
sequence as soon
as user confirms
message.
Stop charging.
A10
The device is
inclined. Please
position device on
a level surface.
MIRUS Controller
inclined
> 25°.
Move the MIRUS
Controller to a
level surface or
turn off via turn off
button.
Alarm or performs
turn OFF
sequence after
user selection.
A11
Mains supply lost!
Restore mains
supply or the
device will turn off
automatically.
AC lost.
Connect AC line
supply or turn off
MIRUS Controller
via turn off button.
Operates on
battery. Performs
turn OFF
sequence after
user selection or if
AC isn't restored
within 30 seconds,
the system shuts
down into OFF
mode.
Содержание Mirus MC DES
Страница 1: ...Additional Information MIRUSTM Controller Software version 2 03 02 Hardware version 2 n...
Страница 28: ...1 Introduction 1 22 MIRUS Controller SW 2 03 02 Additional Information Master en GB Notes...
Страница 48: ...3 General description 3 8 MIRUS Controller SW 2 03 02 Additional Information Master en GB Notes...
Страница 78: ...5 Operation 5 18 MIRUS Controller SW 2 03 02 Additional Information Master en GB Notes...
Страница 92: ...6 Cleaning and maintenance 6 14 MIRUS Controller SW 2 03 02 Additional Information Master en GB Notes...
Страница 118: ...7 Alarms and messages 7 26 MIRUS Controller SW 2 03 02 Additional Information Master en GB Notes...