T a b le 5 (c o n t)
Characteristics
Performance Requirements
Supplemental Inform ation
VE R TIC A L DEFLECTION SYSTEM (cont)
Frequency Response (cont)
+40° C to +55° C
Dc to at least 85 MHz.3
Reduces to 70 MHz at 2 mV per division.3
Ac Coupled Lower —3 dB Point
IX Probe
10 Hz or less.3
10X Probe
1 Hz or less.3
Step Response
5-division reference signal, dc coupled
at all deflection factors, from a 25-J2
source; centered vertically with
VO LTS/D IV VAR control in cali
brated detent. BW L IM IT push button
must be out for fu ll bandwidth
operation.
Perform ance Requirement not checked in Service Manual.
<S>
7 2
2337 Operators
Содержание 2337