Table 5 (cont)
Characteristics
Performance Requirements
Supplemental Information
D IG IT A L M ULTIM ETER (cont)
RMS VOLTS (cont)
Maximum Input Voltage
+ (positive) Input to Ground
500 V (dc + peak ac) at 60 Hz.a
— (negative) Input to Ground
500 V (dc + peak ac) at 60 Hz.a
Positive to Negative Inputs
500 V (dc + peak ac) at 60 Hz a
Resistance
Ranges
2 K£2 (autorange to 200 £2),
200 K£2 (autorange to 20 K£2),
20 M£2 (autorange to 2 M£2).
Resolution (at 200 £2 fu ll scale)
0.1 £2.
Accuracy
+15°C to +35° C
Within ±0.5%, ±1 count +0.4 £2.
—15°C to +15°C
Add 0.05% fo r every °C below +15°C.a
Perform ance Requirement not checked in Service Manual.
@