B TRIGGER SOURCE switch is set to either A TIME
or RUN AFTER DLY. The A TIME (inner knob)
controls the time-measurement point only when the
B TRIGGER SOURCE switch is set to A TIM E. When
the time-measurement point is to the left o f the
reference point, the LCD readout indicates a negative
time difference.
(2?) A AND B SEC/DIV Switches—Selects the sweep
speed for the A and B Sweep generators in a 1-2-5
sequence. The A SEC/DIV switch sets the time
between the B Sweeps (delay time). For calibrated
sweep rates, the TIME (PULL) VAR control must be
in the calibrated detent (fully clockwise position).
A SEC/DIV—The A Sweep speed is shown
between the tw o black lines on the clear plastic
skirt. This switch also selects the delay time (used
in conjunction w ith the B D ELAY TIME POSI
TION control) fo r delayed sweep operation.
B SEC/DIV—The B Sweep speed is set by pulling
the inner knob and rotating it to a setting shown
by the white line scribed on the knob. The B
Sweep circuit is used fo r delayed sweep operation
only.
(22) TIME (PULL) VAR C ontrol—Provides continuously
variable, uncalibrated A Sweep speeds between SEC/
DIV switch settings to at least 2.5 times the cali
brated setting (extends slowest sweep speed to at
least 1.25 s per division). To operate this control, pull
out the VAR knob and rotate it counterclockwise
out o f the detent.
(2?) UNCAL Indicator LED—Illuminates to indicate that
the A Sweep speed is uncalibrated when the TIME
(PULL) VAR control is rotated out o f the calibrated
detent.
(24) HORIZ MODE Switches-Three push-button switches
that select the mode o f operation for the horizontal
deflection system.
A —Horizontal deflection is provided by the A
Sweep generator at a sweep speed determined by
the setting o f the A SEC/DIV switch.
A IN TEN —Horizontal deflection is provided by
the A Sweep generator at a speed determined by
the A SEC/DIV switch. The B Sweep generator
provides an intensified zone on the display. The
@
2337 Operators
11
Содержание 2337
Страница 9: ... ...
Страница 20: ...4119 06 Figure 5 Horizontal controls and indicator ...
Страница 24: ...13 ire 6 A TRIGGER controls connector and indicator ...
Страница 29: ...Figure 7 DMM and B TRIGGER controls connectors and LCD readout 16 2337 Operators ...
Страница 72: ... Figure 22 Delayed sweep magnification ...
Страница 81: ...Figure 27 Time difference between two time related pulses 66 2237 Operators ...
Страница 116: ...NOTES ...
Страница 117: ...NOTES ...