8:IGB µC failure
The microcontroller for the IGB
communication has failed.
•
Check the wiring for EM-compliant
design.
•
The drive controller must be sent in for
repair. Please contact our Service
department.
Yes
9:IGB Lost Frame
IGB motion bus: The subscriber has
detected a loss of at least 2 consecutive
data frames (double error). This cause can
only occur when the IGB state =
3:Motionbus
and the motor is powered.
•
Make sure that all drive controllers in the
IGB network are switched on.
•
Make sure that all connection cables are
plugged in.
Yes
10:IGB P. LostFr
IGB motion bus: A different subscriber has
detected a double error and reported this via
A163
. As a result, this drive controller is also
faulty with this cause. This cause can only
occur when the IGB state =
3:Motionbus
and the motor is powered.
Yes
11:IGB Sync Erro
The synchronization within the drive
controller is faulty as the configuration was
stopped by the commissioning software.
This cause can only occur when the IGB
state =
3:Motionbus
and the motor is
powered.
•
Start the configuration in the drive
controller.
•
If the result occurs with this cause for a
running configuration, the drive
controller must be sent in for repair.
Please contact our Service department
Yes
12:IGB ConfigTim
An IGB Motionbus consumer block or
producer block in the graphical
programming was called up at the wrong
time. The block was called up too early or
closed too late. This cause can only occur
when the IGB state =
3:Motionbus
and the
motor is powered.
Adjust the run-time sequence of the blocks,
transfer the changed configuration to the
drive controller and save it there. Restart the
drive controller.
Yes