ID 442426.04
202
WE KEEP THINGS MOVING
Drive controller
9
Manual SD6
Terminal value of analog output 1 on X100.6 - X100.8.
Scaled value of analog output 1 before limiting and conversion from % to V.
Relative value of analog output 1 before filtering and formation of value.
Enter the coordinates of the parameter whose value will be exported to AA1 in
F40
. As source you can only enter parameters with data type REAL32.
Reference value for the source set in
F40
.
Tau actual value of analog output 1.
Factor of analog output 1.
Activation of formation of value for analog output 1.
Offset of analog output 1.
Lower limit value of analog output 1.
Upper limit value of analog output 1.
E13[0]
analog output 1 terminal value
version 0
E13[1]
analog output 1 scaled value
version 0
E13[2]
analog output 1 relative
version 0
F40
analog output 1 source
version 0
F41
analog output 1 reference source
version 0
F42
analog-output1-act low pass filter
version 0
F43
analog output 1 gain
version 0
F44
analog output1 absolute
version 0
F45
analog output 1 offset
version 0
F46
analog output 1 lower limit
version 0
F47
analog output 1 upper limit
version 0