Drive controller
9
Manual SD6
9.8.3
Analog inputs
9.8.3.1
AE1
Tau for reference value smoothing for analog input 1.
Wire break monitoring for analog input.
Operating mode of the analog input.
Values of the analog input.
•
Element 0: Terminal value of the analog input before filtering.
•
Element 1: Filtered value of the analog input before calibration.
•
Element 2: Calibrated value of the analog input.
Zero value of the analog input.
Maximum positive value of the filtered analog input.
Maximum negative value of the filtered analog input.
Deadband value of the analog input.
Minimum percentage value of the calibrated analog input.
Maximum percentage value of the calibrated analog input.
F13
AE1 ref low pass filter
version 0
F15
wire breakage sensing
version 0
Information
The wire break monitoring function is only possible in AE1 mode
F116=2: 4 to 20mA
.
0: inactive
1: active
F116
AE1-mode selector
version 0
0: -10V to 10V
1: 0 to 20mA
An internal precision resistor (shunt 500 ohms)
is integrated into X100.2. A bridge must be set
between X100.1 and X100.2.
2: 4 to 20mA
An internal precision resistor (shunt 500 ohms)
is integrated into X100.2. A bridge must be set
between X100.1 and X100.2.
E110
AE1
version 0
F110
Analog input 1 zero value
version 0
F111
Analog input 1 maximum positive value
version 0
F112
Analog input 1 maximum negative value
version 0
F113
Analog input 1 deadband value
version 0
F114
Analog input 1 minimum % value
version 0
F115
Analog input 1 maximum % value
version 0