![Stober SD6 Series Скачать руководство пользователя страница 113](http://html.mh-extra.com/html/stober/sd6-series/sd6-series_manual_1381243113.webp)
ID 442426.04
113
WE KEEP THINGS MOVING
Connection
7
Manual SD6
Terminal description X103A
7.4.5
X103B
X103B specification
Pin
Designation
Function
1
BA3
Binary output
2
BA4
3
BA5
4
BA6
Maximum conductor cross-section
Connection type
Maximum conductor cross-section [mm
2
]
Rigid
1,5
Flexible
1,5
Flexible with cable end,
without plastic sleeve
1,5
Flexible with cable end, with
plastic sleeve
0,75
2 leads with the same cross-
section with double cable end
—
4
1
2
3
Information
When the 24 V power fails, binary inputs BE6 to BE13 have signal
status 0 (regardless of the physical signal state).
General specification
Maximum cable
length
30 m, shielded
Electrical data
Binary outputs
BA7 to BA10
Maximum output current 50 mA
Typical voltage drop
< 2 V
Refresh rate
Cycle time of the
application
Binary input BE6
Low level
0 – 8 V
High level
12–30 V
Input voltage
Max. 30 V
Input current
Max. 16 mA
Input frequency