ID 442426.04
204
WE KEEP THINGS MOVING
Drive controller
9
Manual SD6
Terminal value of analog output 2 on X100.7 - X100.8.
Scaled value of analog output 2 before limiting and conversion from % to V.
Relative value of analog output 2 before filtering and formation of value.
Enter the coordinates of the parameter whose value will be exported to AA2 in
F50
. As source you can enter all parameters with data type REAL32.
Reference value for the source set in
F50
.
Tau actual value of analog input 2.
Factor of analog output 2.
Formation of value for analog output 2.
Offset of analog output 2.
Lower limit value of analog output 2.
Upper limit value of analog output 2.
E14[0]
analog output 2 terminal value
version 0
E14[1]
analog output 2 scaled value
version 0
E14[2]
analog output 2 relative
version 0
F50
analog output 2 source
version 0
F51
analog output 2 reference source
version 0
F52
analog-output2-act low pass filter
version 0
F53
analog output 2 gain
version 0
F54
analog output2 absolute
version 0
F55
analog output 2 offset
version 0
F56
analog output 2 lower limit
version 0
F57
analog output 2 upper limit
version 0