Drive controller
9
Manual SD6
9.2.5.1
STOBER device state machine
1
if permissible for the relevant event and if activated in
A29
. Note also the
description of events, see section 16
2
if activated in
A44
9.2.5.2
Device state machine according to CiA 402
1
see section 9.2.2
2
if permissible for the relevant event and if activated in
A29
. Note also the
description of events, see section 16
3
if activated in
A44
9.2.5.3
Parameters
Response of the motor when enable is turned off.
Setting of the source for the
quick stop
signal. The signal triggers a drive quick
stop. Note that the LOW active signal is evaluated, which means that a LOW
level triggers a quick stop.
Display of current value of the
QuickStp
signal (quick stop) on the interface to
the device controller (configuration, module 100107).
The
quick stop
signal triggers a drive quick stop.
I17
is the defined
deceleration, which in turn is the determining factor for the braking time (see
also
A39
and
A45
).
Quick stop deceleration.
Corresponds to object index 6085
hex
subindex 0
hex
Quick stop deceleration
in
accordance with CiA 402.
Quick stop output of the device control unit to the axis/axes. Indicates that the
device control unit will force a quick stop that will be performed in speed
control. Reference value processing of the axis must support this quick stop
with a higher priority than axis reference value processing.
Quick stop
A62
>1
Fault quick stop
1
Enable
2
BE1
2:Parameter
1
1
4:BE1-inverted
5:BE2
6:BE2-inverted
1:High
0:Low
E19.1
E19.2
3:BE1
.
.
.
BE2
Quick stop
>1
Fault quick stop
2
Enable
3
Quickstop command
1
A44
enable quick-stop
version 0
A62
/quick stop source
version 0
A302
/quick stop
version 0
A578
Quick stop deceleration
version 1
A901
sysQuickstopOut
version 0