ID 442426.04
157
WE KEEP THINGS MOVING
Drive controller
9
Manual SD6
9.1
Introduction
This section describes basic settings that must be considered in each project
for the drive controller and adjusted for your application. Examples include
selecting a device state machine, parameterization of power input or setting
and calibrating analog inputs.
9.2
Device controller
9.2.1
STOBER device state machine
The STOBER device state machine recognizes the following states:
The illustration below shows which changes of state are possible.
Fig. 9-1 STOBER device state machine
Designation
Behavior
Not ready to
switch on
•
Power is supplied to the electronics.
•
The self test is running.
•
Initialization is running.
•
No torque is assigned.
Switch on disable
•
Software/hardware initialization is complete.
•
The application can be reparameterized.
•
No torque is assigned.
•
The safety technology can be active.
Ready to switch
on
•
The application can be reparameterized.
•
No torque is assigned.
Switched on
•
The application can be reparameterized.
•
No torque is assigned.
Operation
enabled
•
The application can be partially parameterized.
•
A torque is assigned.
Fault
•
The application can be parameterized.
•
No torque is assigned.
Fault response
active
•
The application can be partially reparameterized.
•
An error-dependent action is being performed (lock
drive function or quick stop).
•
A torque can be assigned.
Quick stop active
•
The application can be partially reparameterized.
•
The quick stop function is being performed.
•
A torque is assigned.
Designation
Behavior
Nicht Einschaltbereit
Einschaltsperre
Einschaltbereit
Eingeschaltet
Betrieb freigegeben
Schnellhalt aktiv
Störung
Störungsreaktion aktiv
0
2
1
3
4
5
6
9
7
8
11
12
14
13
15
16
10
Not ready for switchon
Fault reaction active
Fault
Quick stop active
Switchon disable
Ready for switchon
Switched on
Operation enabled