Display of the current operating state according to the operating display. Useful
for fieldbus queries.
9.2.2.1
Controlword and Statusword
Control word.
3
Motion bus
The IGB motion bus is projected, but:
•
A124 IGB exception state
is not activated or
•
A155 IGB-state
is not equal to 3 or
•
The IGB motion bus is not synchronized (see
A182 IGB motion bus conditions
).
4
STO
The STO safety function is active
(Safe Torque Off).
5
Quick stop
CiA 402 only:
The command (control word
A515
, bit 0, 1, 2, 3,
7) is Quick stop.
6
Control word
CiA 402 only:
The command (control word
A515
, bit 0, 1, 2, 3,
7) is not Shutdown.
7
Reserved
—
E80
operating condition
version 1
Bit
Description
Comment
A515
control word
version 1
Bit
Description
Comment
0
Switch on
1
Enable voltage
2
Quick stop
1 = No quick stop
requested
3
Enable operation
4 - 5 Operation mode specific
Depends on the active
operating mode
A542
See table of operating
mode depends bits
6
Operation mode specific
No function
7
Fault reset
8
Optional
No function
9
Operation mode specific
No function
10
Reserved
Reserved
11
Manufacturer specific
Axis selector bit 0
If
A63
is set to parameter
12
Manufacturer specific
Axis selector bit 1
If
A64
is set to parameter
13
Manufacturer specific
Axis disable
If
A65
is set to parameter