![Stober SD6 Series Скачать руководство пользователя страница 104](http://html.mh-extra.com/html/stober/sd6-series/sd6-series_manual_1381243104.webp)
ID 442426.04
104
WE KEEP THINGS MOVING
Connection
7
Manual SD6
7.3.10
X3A, X3B: PC, IGB
You can implement the functions of the IGB (Integrated Bus) with the X3A and
X3B interfaces:
•
Direct connection to the PC
•
IGB Motionbus
•
Remote maintenance
Terminal description X3A and X3B
Cable specification
STOBER provides ready-made cables for
•
direct connection PC - drive controller and
•
to set up the Integrated Bus.
These cables must be used to ensure proper functionality.
It is also possible to use cables with the following specification:
7.3.11
X4: Encoder
NOTICE
Danger of encoder destruction!
X4 may not be connected or disconnected when the device is on!
Pin
Designation
Function
1
Ethernet communication
2
TxData-
3
R
4
—
Not used
5
—
6
RecvData-
Ethernet communication
7
—
Not used
8
—
Plug wiring
Patch or crossover
Quality
CAT5e
Shielding
SFTP or PIMF
General specification
U
2
5-15 V (see encoder supply)
I
2max
X4: 250 mA
Sum X4, X120, X140: 500 mA
I
2min
13 mA
Maximum cable
length
100 m
Specification for EnDat 2.1
Encoder type
Single and Multiturn, not suitable for linear encoders
Switching frequency
2 MHz
Specification for EnDat 2.2
Encoder type
Single-turn and multiturn
Switching frequency
4 MHz
SSI specification
Switching frequency
250 kHz
Sampling rate
250 µs
Code
Binary or Gray