![Stober SD6 Series Скачать руководство пользователя страница 173](http://html.mh-extra.com/html/stober/sd6-series/sd6-series_manual_1381243173.webp)
ID 442426.04
173
WE KEEP THINGS MOVING
Drive controller
9
Manual SD6
The level of the X1.Enable binary signal is displayed inverted.
Additional enable signal of the axis to the device control unit. It is logically
ANDED with the enable signal (normally from binary input X1.enable) in the
device control unit.
Terminal value of the binary inputs and of the enable.
9.2.4
Auto-start
WARNING!
Unexpected startup of motor!
If auto-start is active, the drive controller can change immediately from device
state
switchOnDis.
to
Operation enabled
!
Note the description of the STOBER device state machine.
Use auto-start only if this response is permissible, taking into consideration
the standards and regulations that apply to the system or machine.
Auto-start can only be used with STOBER device state machine (see section
9.2.1 STOBER device state machine).
If auto-start
A34
=
1:active
, the drive controller changes from device state
switchOnDis.
to
readySwtchOn
even if enable is active.
Activation of auto-start for the STOBER device state machine.
WARNING!
Unexpected startup of motor!
If auto-start is active, the drive controller can change immediately from device
state
switchOnDis.
to
Operation enabled
!
Note the description of the STOBER device state machine.
Use auto-start only if this response is permissible, taking into consideration
the standards and regulations that apply to the system or machine.
A307
X1.Enabled inverted
version 0
A910
sysAdditionalEnableIn
version 0
Information
If DriveControlSuite sets up a connection to the drive controller, this
parameter is always read if
Write parameters
was specified as the
data direction in DriveControlSuite.
E19
binary inputs
version 0
Bit
Description
Comment
0
Enable
1 -
13
Binary input 1 to binary input 13
14 -
15
Reserved
No function
A34
auto-start
version 0