![Stober SD6 Series Скачать руководство пользователя страница 127](http://html.mh-extra.com/html/stober/sd6-series/sd6-series_manual_1381243127.webp)
ID 442426.04
127
WE KEEP THINGS MOVING
Connection
7
Manual SD6
7.6.6
X303
Terminal description X303
7.6.7
X304: Connection via D-sub connector
WARNING!
Danger of personal injury and material damage due to electric shock!
There is no potential separation in the LA6 adapter box.
Signals of the motor temperature sensor without potential separation must
not be routed via LA6. Instead they must be connected directly to the drive
controller (terminal X2).
General specification
U
1
20.4-28.8 V
I
1max
100 mA
Pin
Designation
Function
1
+ 24 V
24-V power supply
2
GND
Reference potential for + 24 V
+
–
General specification
U
2
5 V
I
2max
250 mA
I
2min
13 mA
Maximum cable
length
100 m
Specification for incremental signals
f
max
≤
1 MHz
Signal level
TTL
Calculation example
– limit frequency
... for encoder with 2,048 pulses per revolution:
3,000 revolutions per minute (equivalent to 50 revolutions per
second) * 2,048 pulses per revolution
= 102,400 pulses per second
= 102.4 kHz