Communications
10.2 Acyclic data exchange
SIPLUS HCS4200 PROFINET/PROFIBUS DP
164
Operating Instructions, 07/2019, A5E35066204A/006
10.2.1
Acyclic output data
Data record 100 "Field type 1"
The data set describes an HCS function and addresses the HCS.
Byte
Description
0, 1
Start channel for field 1
2, 3
End channel for field 1
...
...
124,125 Start channel for field 32
126,127 End channel for field 32
Using this dataset, fields of type 1 can be defined. This field type comprises one channel
range that is described by the first and last channel of the field.
Application range: Thermoforming, clustering of adjacent channels
Definition is via an array [1 ... 32] with two elements of type "Word". Up to 32 fields can be
defined.
The field number corresponds to the array index.
Field number 0 cannot be used. It exists automatically in the HCS and contains all the
channels of the HCS by default. Production and standby setpoints are preset to 100 %.
All channels that are not explicitly assigned to a new field remain in this default field.
To use fields, the user must ensure that all the existing channels are assigned to a user field.
A field can be erased by entering a 0 for the number of the start channel and the end
channel.
Note
When a dataset 100 is written, it is no longer possible to use the datasets for field type 2.