Communications
10.2 Acyclic data exchange
SIPLUS HCS4200 PROFINET/PROFIBUS DP
Operating Instructions, 07/2019, A5E35066204A/006
165
Data record 101 to 132 "Field type 2"
The data sets describe an HCS function and address the HCS.
Byte
Description
0, 1
Number of channel 1 of field (dataset number minus 100)
1,2
Number of channel 2 of field (dataset number minus 100)
…
...
44,45
Number of channel 23 of field (dataset number minus 100)
46,47
Number of channel 24 of field (dataset number minus 100)
Using these datasets, fields of type 2 can be defined. This field type comprises channels that
are directly assigned.
Application range: Blow-molding, forming a layer over all POMs (e.g. every first channel
of a POM).
Definition is performed directly via the type "Word". Up to 24 channels can be defined.
The field number corresponds to the dataset number minus 100.
Field number 0 cannot be used. It exists automatically in the HCS and contains all the
channels of the HCS by default. Production and standby setpoints are preset to 100 %.
All channels that are not explicitly assigned to a new field remain in this default field. To use
fields, the user must ensure that all the existing channels are assigned to a user field.
A field can be erased by entering a 0 for all channels ("all" refers to the dataset length).
Note
When one of the datasets 101 to 132 is written, it is no longer possible to use the dataset for
field type 1.
Data record 150 "Production field value"
The data set describes an HCS function and addresses the HCS.
Byte
Description
0
Setpoint for field 1
1
Setpoint for field 2
...
...
31
Setpoint for field 32
Definition is via an array [1 ... 32] with one element of type "Byte".
The field number corresponds to the array index.