Communications
10.2 Acyclic data exchange
SIPLUS HCS4200 PROFINET/PROFIBUS DP
166
Operating Instructions, 07/2019, A5E35066204A/006
Data set 151 "Standby field value"
The data set describes an HCS function and addresses the HCS.
Byte
Description
0
Setpoint for field 1
1
Setpoint for field 2
...
...
31
Setpoint for field 32
Definition is via an array [1..32] with one element of type "Byte".
The field number corresponds to the array index.
Dataset 152 "Channels without diagnostic alarm"
The data set describes an HCS function and addresses the HCS.
Byte
Bit
Description
0
0
Setting for channel 1
0: Error message is output (default)
1: Error message is suppressed
1
Setting for channel 2
2
Setting for channel 3
3
Setting for channel 4
4
Setting for channel 5
5
Setting for channel 6
6
Setting for channel 7
7
Setting for channel 8
1
0 … 7
Setting for channels 9 … 16
2
0 … 7
Setting for channels 17 … 24
3
0 … 7
Setting for channel 25 … 32
4
0 … 7
Setting for channels 33 … 40
5
0 … 7
Setting for channels 41 … 48
...
...
...
23
0 … 7
Setting for channels 185 ... 192
...
...
...
47
0 ... 7
Setting for channels 377 … 384
PROFINET: Definition is via an array [1 … 384] with one element of type "Bool".
PROFIBUS: Definition is via an array [1 … 192] with one element of type "Bool".
Each bit is assigned to one channel. The size of the array depends on the maximum
configuration possible for the HCS (number of POMs, number of channels per POM).