xxiii
Date Code 20170814
Instruction Manual
SEL-700G Relay
Preface
Safety Information
Safety Symbols
The following symbols are often marked on SEL products.
Safety Marks
The following statements apply to this device.
CAUTION
Refer to accompanying documents.
ATTENTION
Se reporter à la documentation.
Earth (ground)
Terre
Protective earth (ground)
Terre de protection
Direct current
Courant continu
Alternating current
Courant alternatif
Both direct and alternating current
Courant continu et alternatif
Instruction manual
Manuel d’instructions
General Safety Marks
CAUTION
There is danger of explosion if the battery is incorrectly replaced.
Replace only with Ray-O-Vac no. BR2335 or equivalent recommended
by manufacturer. See Owner's Manual for safety instructions. The
battery used in this device may present a fire or chemical burn hazard
if mistreated. Do not recharge, disassemble, heat above 100°C or
incinerate. Dispose of used batteries according to the manufacturer’s
instructions. Keep battery out of reach of children.
ATTENTION
Une pile remplacée incorrectement pose des risques d’explosion.
Remplacez seulement avec un Ray-O-Vac no BR2335 ou un produit
équivalent recommandé par le fabricant. Voir le guide d’utilisateur
pour les instructions de sécurité. La pile utilisée dans cet appareil peut
présenter un risque d’incendie ou de brûlure chimique si vous en faites
mauvais usage. Ne pas recharger, démonter, chauffer à plus de 100°C
ou incinérer. Éliminez les vieilles piles suivant les instructions du
fabricant. Gardez la pile hors de la portée des enfants.
For use in Pollution Degree 2 environment.
Pour l'utilisation dans un environnement de Degré de Pollution 2.
Ambient air temperature shall not exceed 50°C (122°F).
La température de l'air ambiant ne doit pas dépasser 50°C (122°F).
For use on a flat surface of a Type 1 enclosure.
Destiné à l'utilisation sur une surface plane d'un boîtier de
Type 1.
Terminal Ratings
Wire Material
Use 75°C (167°F) copper conductors only.
Spécifications des bornes
Type de filage
Utiliser seulement conducteurs en cuivre 75°C (167°F).
Tightening Torque
Terminal Block: 0.9–1.4 Nm (8–12 in-lb)
Compression Plug: 0.5–1.0 Nm (4.4–8.8 in-lb)
Compression Plug Mounting Ear Screw: 0.18–0.25 Nm
(1.6–2.2 in-lb)
Couple de serrage
Bornier : 0,9–1,4 (8–12 livres-pouce)
Fiche à compression : 0,5–1,0 Nm (4,4–8,8 livres-pouce)
Vis à oreille de montage de la fiche à compression :
0,18–0,25 Nm (1,6–2,2 livres-pouce)
Hazardous Locations Safety Marks
WARNING – EXPLOSION HAZARD
Open circuit before removing cover.
AVERTISSEMENT – DANGER D'EXPLOSION
Ouvrir le circuit avant de déposer le couvercle.
WARNING – EXPLOSION HAZARD
Substitution of components may impair suitability for Class I,
Division 2.
AVERTISSEMENT – DANGER D'EXPLOSION
La substitution de composants peut détériorer la conformité à
Classe I, Division 2.
Ambient air temperature shall not exceed 50°C (122°F).
La température de l'air ambiant ne doit pas dépasser 50°C
(122°F).
Содержание SEL-700G Series
Страница 14: ...This page intentionally left blank ...
Страница 22: ...This page intentionally left blank ...
Страница 32: ...This page intentionally left blank ...
Страница 52: ...This page intentionally left blank ...
Страница 106: ...This page intentionally left blank ...
Страница 510: ...This page intentionally left blank ...
Страница 560: ...This page intentionally left blank ...
Страница 578: ...This page intentionally left blank ...
Страница 588: ...This page intentionally left blank ...
Страница 604: ...This page intentionally left blank ...
Страница 634: ...This page intentionally left blank ...
Страница 738: ...This page intentionally left blank ...
Страница 802: ...This page intentionally left blank ...
Страница 816: ...This page intentionally left blank ...