J.11
Date Code 20170814
Instruction Manual
SEL-700G Relay
Relay Word Bits
Definitions
50PDIRY
Three-phase overcurrent threshold exceeded
141
50PX1P
X-side Level 1 phase instantaneous overcurrent element pickup
1
50PX1T
X-side Level 1 phase instantaneous overcurrent element trip
1
50PX2P
X-side Level 2 phase instantaneous overcurrent element pickup
1
50PX2T
X-side Level 2 phase instantaneous overcurrent element trip
1
50PX3AP
X-side Level 3 Phase A instantaneous overcurrent element pickup
2
50PX3AT
X-side Level 3 Phase A instantaneous overcurrent element trip
2
50PX3BP
X-side Level 3 Phase B instantaneous overcurrent element pickup
2
50PX3BT
X-side Level 3 Phase B instantaneous overcurrent element trip
2
50PX3CP
X-side Level 3 Phase C instantaneous overcurrent element pickup
2
50PX3CT
X-side Level 3 Phase C instantaneous overcurrent element trip
2
50PY1P
Y-side Level 1 phase instantaneous overcurrent element pickup
1
50PY1T
Y-side Level 1 phase instantaneous overcurrent element trip
1
50PY2P
Y-side Level 2 phase instantaneous overcurrent element pickup
1
50PY2T
Y-side Level 2 phase instantaneous overcurrent element trip
1
50PY3AP
Y-side Level 3 Phase A instantaneous overcurrent element pickup
3
50PY3AT
Y-side Level 3 Phase A instantaneous overcurrent element trip
3
50PY3BP
Y-side Level 3 Phase B instantaneous overcurrent element pickup
3
50PY3BT
Y-side Level 3 Phase B instantaneous overcurrent element trip
3
50PY3CP
Y-side Level 3 Phase C instantaneous overcurrent element pickup
3
50PY3CT
Y-side Level 3 Phase C instantaneous overcurrent element trip
3
50QFX
X-side forward-direction negative-sequence overcurrent threshold exceeded
135
50QFY
Y-side forward-direction negative-sequence overcurrent threshold exceeded
136
50QRX
X-side reverse direction negative-sequence overcurrent threshold exceeded
135
50QRY
Y-side reverse direction negative-sequence overcurrent threshold exceeded
136
50QX1P
X-side Level 1 negative-sequence instantaneous overcurrent element pickup
4
50QX1T
X-side Level 1 negative-sequence instantaneous overcurrent element trip
4
50QX2P
X-side Level 2 negative-sequence instantaneous overcurrent element pickup
4
50QX2T
X-side Level 2 negative-sequence instantaneous overcurrent element trip
4
50QY1P
Y-side Level 1 negative-sequence instantaneous overcurrent element pickup
5
50QY1T
Y-side Level 1 negative-sequence instantaneous overcurrent element trip
5
50QY2P
Y-side Level 2 residual-ground instantaneous overcurrent element pickup
5
50QY2T
Y-side Level 2 residual-ground instantaneous overcurrent element trip
5
51C
Voltage-controlled phase time-overcurrent element pickup (maximum phase current
above pickup setting 51CP)
14
Table J.3
Relay Word Bit Definitions for the SEL-700G
(Sheet 5 of 22)
Bit
Definition
Row
Содержание SEL-700G Series
Страница 14: ...This page intentionally left blank ...
Страница 22: ...This page intentionally left blank ...
Страница 32: ...This page intentionally left blank ...
Страница 52: ...This page intentionally left blank ...
Страница 106: ...This page intentionally left blank ...
Страница 510: ...This page intentionally left blank ...
Страница 560: ...This page intentionally left blank ...
Страница 578: ...This page intentionally left blank ...
Страница 588: ...This page intentionally left blank ...
Страница 604: ...This page intentionally left blank ...
Страница 634: ...This page intentionally left blank ...
Страница 738: ...This page intentionally left blank ...
Страница 802: ...This page intentionally left blank ...
Страница 816: ...This page intentionally left blank ...