96
Installation manual of system “bp408” - Commissioning
Switching on the inspection control deletes all calls and the command transmitters
for car calls, hall calls and for higher-level control systems are switched off. All
devices of the safety circuit remain effective.
If the lift is switched back to normal operation, a correction run for the floor counter
can be triggered after a call. For control systems with an absolute encoder, no
correction run is necessary.
8.8
Inspection control Shaft pit
The inspection control in the shaft pit serves for testing and maintenance purposes.
The return to normal operation of the lift may only take place after resetting the
inspection switch to its normal position and must call for the intervention of a
competent person responsible for the maintenance.
In addition, a return to normal operation effected in the shaft pit by the inspection
control may only take place under the following conditions:
Shaft doors, which allow access to the shaft pit, are closed and locked
all emergency brake switches in the shaft pit are not actuated
an electric reset device outside the shaft is actuated
Содержание bp408
Страница 2: ......
Страница 24: ...24 Installation manual of system bp408 Safety instructions...
Страница 52: ...52 Installation manual of system bp408 The control system bp408...
Страница 58: ...58 Installation manual of system bp408 Installation and assembly...
Страница 80: ...80 Installation manual of system bp408 Electrical connection...
Страница 118: ...Installation manual of system bp408 Appendix 118 Appendix A Menu navigation bp408...
Страница 119: ...119 Installation manual of system bp408 Appendix B Update of the firmware via USB stick...