5.7.13
Optional equipment
5.7.13.1
Uninterruptible Power Supply (UPS)
Böhnke + Partner GmbH supplies control systems for the lift industry. Optionally,
the control system ordered by you can be equipped with a UPS, which should
contribute to function preservation of emergency operation in case of power failure.
The compact and powerful UPS used by us is part of the newest generation of
UPS devices. High reliability, low operating costs and excellent electrical properties
are important advantages of the technology used.
The efficiency of the UPS system is designed on site for the use that you specify.
As the UPS system must be operational in an emergency, the operational
readiness must be checked regularly.
The operator is responsible for constant operational readiness of the UPS. He can
transfer this task to the company entrusted with the maintenance work of the lift.
CAUTION!
Before the UPS is installed or put in operation, the operation manual of the UPS
must be carefully read and all instructions, guidance and safety instructions
regarding installation and commissioning must be followed.
The operation manual must be always be stored at the UPS for later use.
All maintenance work may only be carried out by qualified and trained skilled
personnel.
Do not try to repair or maintain the UPS yourself.
When opening the casing or removing covers, voltage-carrying elements are
exposed.
Contact with these may be fatal.
Böhnke + Partner GmbH does not assume responsibility for consequential
damages that were caused due to faulty manipulation of the UPS. Only the
commitment of manufacturer of the UPS supplied applies.
5.7.13.2
Operational readiness of the UPS system
Böhnke + Partner GmbH supplies control systems with integrated UPSs and
expects operational installation of components within four months.
If the UPS system is not immediately installed, it must be stored in a place, in which
the temperature lies b5° and +40°C and the relative humidity is always
below 90%. If the transport container has been removed, the UPS must also be
protected from dust.
The UPS system contains tightly sealed, maintenance-free lead batteries, which
however can suffer damage if they are stored for a long time in discharged state
or are exposed to high temperature. Therefore, the storage time must not exceed:
six months at +20°C, three months at +30°C and two months at +35°C, without
Содержание bp408
Страница 2: ......
Страница 24: ...24 Installation manual of system bp408 Safety instructions...
Страница 52: ...52 Installation manual of system bp408 The control system bp408...
Страница 58: ...58 Installation manual of system bp408 Installation and assembly...
Страница 80: ...80 Installation manual of system bp408 Electrical connection...
Страница 118: ...Installation manual of system bp408 Appendix 118 Appendix A Menu navigation bp408...
Страница 119: ...119 Installation manual of system bp408 Appendix B Update of the firmware via USB stick...