
Installation manual of system “bp408” - Commissioning
97
The lift control system supports two different electrical reset devices:
Reset by means of Key Switch
Reset by means of drive command transmitter
8.8.1
Reset by means of key switch
The return to normal operation is carried out by operating the key switch “Reset
Shaft Pit Inspection (805)" and in compliance with the above-mentioned conditions
by the control system.
The reset by means of key switch is allowed for individual and group control
systems.
8.8.2
Reset by means of drive command transmitter
The reset by means of the drive command transmitter is only applicable for
individual control systems and not allowed for group control systems.
In the lift control system, at least one access
of the lowest floor must be set, from which an
electrical reset is accepted.
This setting can be made in the setup menu
under
Features > Control system > Special functions >
Floor/door for return to normal operation
.
Figure 56:
Setting the access for leaving the shaft pit
Содержание bp408
Страница 2: ......
Страница 24: ...24 Installation manual of system bp408 Safety instructions...
Страница 52: ...52 Installation manual of system bp408 The control system bp408...
Страница 58: ...58 Installation manual of system bp408 Installation and assembly...
Страница 80: ...80 Installation manual of system bp408 Electrical connection...
Страница 118: ...Installation manual of system bp408 Appendix 118 Appendix A Menu navigation bp408...
Страница 119: ...119 Installation manual of system bp408 Appendix B Update of the firmware via USB stick...