Installation manual of system “bp408” - Commissioning
Now, drive to every floor from both directions of travel and check whether the lift
does a levelled drive-in. For this, use the levelling test under
DIAGNOSIS > SHAFT SIGNALS > LEVELLING TEST
.
If the lift does not stop at the previously set
position, the
BRAKING DISTANCE V0 (STOPPING DISTANCE)
can be adjusted under
FUNCTIONS > DRIVE
.
The sensitivity of the readjustment range can
be set independent of the levelling range.
Refer to service menu:
TIMES > DRIVE / READJUST DECELERATION
TIME
8.11.4
Drive speeds
The drive speeds are set in the service menu in the menu option
SETTING> FUNCTIONS > DRIVE
.
Abbreviation for the name of the speed:
VN =
Readjusted speed
VI =
Inspection speed
VR =
Return speed
V0 =
Drive-in speed
V1..V7 Intermediate speeds and fast speed, depending on the set drive type.
In case of a change in the drive speeds, a calculation of the braking and minimum
drive distances will be offered. These must be adjusted, if necessary.
NOTE!
V0 < V1 < V2 < V3 < V4 < V5 < V6 < V7!
Figure 66:
Levelling test
Figure 67:
Drive curve in the example of a DCP3 connection with V4 as nominal speed
Содержание bp408
Страница 2: ......
Страница 24: ...24 Installation manual of system bp408 Safety instructions...
Страница 52: ...52 Installation manual of system bp408 The control system bp408...
Страница 58: ...58 Installation manual of system bp408 Installation and assembly...
Страница 80: ...80 Installation manual of system bp408 Electrical connection...
Страница 118: ...Installation manual of system bp408 Appendix 118 Appendix A Menu navigation bp408...
Страница 119: ...119 Installation manual of system bp408 Appendix B Update of the firmware via USB stick...