Serial Communications
Page 7-1
_________________________________________________________________
Section 7 Serial Communications
The Model
2010D
incorporates a serial RS-232 port, which can be
attached
to
a
modem
or
personal
computer
for
remote
configuration, operation, control and for updating the operating
program.
The remote terminal feature allows a user to remotely interact
with the
2010D
. While in this "terminal mode", the user can
view
an exact image of the
2010D
'
s display on a remote terminal
screen
and access any function that is available on the unit’s front
panel.
In addition to terminal mode, the Model
2010D
supports a serial
command mode. This mode makes it possible to interact with the
unit via the serial communications port using a protocol more
suitable for remote control by a computer.
Using serial commands, sequences and points can be started or
stopped and several other
2010D
features can be accessed. This
capability opens up a number of applications involving remote
control of the Model
2010D
by local or remotely located PCs or
direct control by a datalogger.
Operating Modes
There are two modes of operation for the serial ports: terminal
mode and command mode. Terminal mode allows a user to interact
with the
2010D
using a remote terminal. Command mode allows
another computer or datalogger to control and monitor the
2010D
using a command protocol. Both operating modes may be used on
the same serial port, however the correct mode of operation must
be selected first. Following are descriptions of how to change
modes.
Terminal Mode
If the remote terminal is enabled when
the
2010D
first powers up, the terminal
mode will automatically be selected and
a log-in will be requested. If command
mode is active, terminal mode can be
selected by pressing the ESC key twice
in succession. This will cause the
2010D
screen to appear on the remote
terminal.
Содержание 2010D
Страница 1: ...MODEL 2010D GAS DILUTION CALIBRATOR OPERATIONS MANUAL I N S T R U M E N T S...
Страница 3: ......
Страница 20: ...System Operations Page 3 2 Figure 3 1 The Model 2010D Front Panel...
Страница 42: ...Installation Page 4 15 Figure 4 1 Rear Panel...
Страница 63: ...Operation Page 5 7 Figure 5 5 The Dilution Status Screen Figure 5 6 The Ozone Status Screen...
Страница 177: ...MODEL 2010D GAS DILUTION CALIBRATOR SCHEMATICS...
Страница 178: ......
Страница 182: ...INSTRUMENTS 2548 Shell Road Units A D Georgetown Texas 78628 Phone 512 869 0544Fax 512 869 0993 sales sabio com...