NB-IoT NPRACH Measurement
R&S
®
CMW-KM300/-KS300
350
User Manual 1178.5689.02 ─ 06
Characteristics
Refer to 3GPP TS 36.521 V14.4.0, section...
Specified limit
ON power
6.3.4F.2 NPRACH Time Mask for Category NB1
≥ -18.5 dBm, ≤ -3.5 dBm
OFF power
6.3.4F.2 NPRACH Time Mask for Category NB1
≤ -48.5 dBm
Power dynamics limit settings
The limits for ON and OFF power can be set in the configuration dialog.
Figure 4-18: Power dynamics limit settings
Remote command:
CONFigure:NIOT:MEAS<i>:PRACh:LIMit:PDYNamics
4.3.7
Shortcut Configuration
Access: "Config" hotkey > "Generator Shortcut" setting.
This section configures a shortcut softkey that provides a fast way to access the GPRF
generator from the measurement.
The setting is a common measurement setting. It has the same value in all NB-IoT
measurements (NPRACH measurement and multi-evaluation measurement).
Figure 4-19: Shortcut configuration
Generator Shortcut
Selects a GPRF generator instance. Softkeys for the selected instance are added to
the softkey panel.
4.3.8
Additional Softkeys and Hotkeys
See
Chapter 3.3.8, "Additional Softkeys and Hotkeys"
4.4
Programming
The following sections provide programming examples for the NB-IoT NPRACH mea-
surement.
Programming