NB-IoT Signaling
R&S
®
CMW-KM300/-KS300
193
User Manual 1178.5689.02 ─ 06
<BLER>
Block error ratio (percentage of sent scheduled subframes for
which no ACK has been received)
Range:
0 % to 100 %
Default unit: %
<ThroughputRel>
Average throughput (as percentage of maximum reachable
throughput)
Range:
0 % to 100 %
Default unit: %
<DTX>
Percentage of sent scheduled subframes for which no ACK and
no NACK has been received
Range:
0 % to 100 %
Default unit: %
Example:
See
Configuring a BLER Measurement
Usage:
Query only
Firmware/Software:
V3.7.20
Manual operation:
See
FETCh:NIOT:SIGN<i>:BLER:UL:ABSolute?
Returns the uplink results of the BLER measurement.
Return values:
<Reliability>
See
<CRC Pass>
Number of received subframes with passed CRC check
Range:
0 to 2E+9
<CRC Fail>
Number of received subframes with failed CRC check
Range:
0 to 2E+9
<Throughput abs>
Average uplink throughput
Range:
0 bit/s to 200E+6 bit/s
<DTX>
Number of sent scheduled UL subframes for which no data has
been received
Range:
0 to 2E+9
Example:
See
Configuring a BLER Measurement
Usage:
Query only
Firmware/Software:
V3.7.50
Manual operation:
See
FETCh:NIOT:SIGN<i>:BLER:UL:RELative?
Returns the uplink results of the BLER measurement.
Command Reference
深圳德标仪器