NB-IoT Signaling
R&S
®
CMW-KM300/-KS300
81
User Manual 1178.5689.02 ─ 06
Figure 2-49: Connection configuration settings
............................................................................................. 81
...................................................................................... 82
Default Paging Cycle
Selects the cell-specific default paging cycle (128, 256, 512 or 1024 radio frames). The
value is signaled to the UE as "defaultPagingCycle" and used by the UE as input for
the calculation of paging radio frame and subframe positions.
The R&S
CMW considers the setting when sending paging messages.
Remote command:
CONFigure:NIOT:SIGN<i>:CONNection:DPCYcle
PCCH-Config nB
Configures the field "nB" in the "PCCH-Config-NB" in system information block 2.
The value is used by the UE as input for the calculation of paging radio frame and pag-
ing occasion according to 3GPP TS 36.304, chapter 7.
Remote command:
CONFigure:NIOT:SIGN<i>:CONNection:PCNB
BCCH Mod. Period Coeff.
Configures the field "modificationPeriodCoeff" in the "BCCH-Config-NB" in system
information block 2.
Remote command:
CONFigure:NIOT:SIGN<i>:CONNection:BMPC
PSM Allowed
Specifies whether a UE request for power-saving mode (PSM) is accepted or rejected.
See also 3GPP TS 24.301, section 5.3.11 "Power saving mode".
If you enable the checkbox, a PSM request is answered with timer T3324, see
Remote command:
CONFigure:NIOT:SIGN<i>:CONNection:PSMallowed