NB-IoT Multi-Evaluation Measurement
R&S
®
CMW-KM300/-KS300
270
User Manual 1178.5689.02 ─ 06
3.5.3.2
Enabling Results and Views
The following commands select the evaluated results and the displayed views.
CONFigure:NIOT:MEAS<i>:MEValuation:RESult[:ALL]
.......................................................270
CONFigure:NIOT:MEAS<i>:MEValuation:RESult:EVMagnitude
...........................................271
CONFigure:NIOT:MEAS<i>:MEValuation:RESult:MERRor
..................................................271
CONFigure:NIOT:MEAS<i>:MEValuation:RESult:PERRor
.................................................. 271
CONFigure:NIOT:MEAS<i>:MEValuation:RESult:IEMissions
.............................................. 271
CONFigure:NIOT:MEAS<i>:MEValuation:RESult:IQ
...........................................................271
CONFigure:NIOT:MEAS<i>:MEValuation:RESult:TXM
....................................................... 271
CONFigure:NIOT:MEAS<i>:MEValuation:RESult:SEMask
.................................................. 271
CONFigure:NIOT:MEAS<i>:MEValuation:RESult:ACLR
..................................................... 271
CONFigure:NIOT:MEAS<i>:MEValuation:RESult:PMONitor
................................................271
CONFigure:NIOT:MEAS<i>:MEValuation:RESult:PDYNamics
.............................................271
CONFigure:NIOT:MEAS<i>:MEValuation:RESult[:ALL]
<EVM>, <MagnitudeError>,
<PhaseError>, <InbandEmissions>, <IQ>, <TXMeasurement>, <SpecEmMask>,
<ACLR>[, <PowerMonitor>, <PowerDynamics>]
Enables or disables the evaluation of results and shows or hides the views in the multi-
evaluation measurement. This command combines most other
CONFigure:NIOT:MEAS<i>:MEValuation:RESult...
commands.
Parameters:
<EVM>
OFF | ON
Error vector magnitude
OFF:
Do not evaluate results, hide the view
ON:
Evaluate results and show the view
*RST:
ON
<MagnitudeError>
OFF | ON
*RST:
ON
<PhaseError>
OFF | ON
*RST:
OFF
<InbandEmissions>
OFF | ON
*RST:
ON
<IQ>
OFF | ON
I/Q constellation diagram
*RST:
OFF
<TXMeasurement>
OFF | ON
TX measurement statistical overview
*RST:
ON
<SpecEmMask>
OFF | ON
Spectrum emission mask
*RST:
ON
Command Reference