NB-IoT Signaling
R&S
®
CMW-KM300/-KS300
142
User Manual 1178.5689.02 ─ 06
CONFigure:NIOT:SIGN<i>:UL:NPUSch:ULNPower
........................................................... 142
SENSe:NIOT:SIGN<i>:UL:ADPower:ENPPpower?
............................................................ 142
SENSe:NIOT:SIGN<i>:UL:ADPower:EFNPower<format>?
................................................. 142
CONFigure:NIOT:SIGN<i>:UL:PMAX
............................................................................... 143
CONFigure:NIOT:SIGN<i>:UL:NPUSch:ULNPower
<Power>
Defines a cell-specific nominal power value for maximum subcarrier allocation in the
UL. The maximum allowed allocation depends on the subcarrier spacing.
This command is only relevant for basic configuration and rejected if advanced config-
uration is active.
Parameters:
<Power>
Range:
-50 dBm to 34 dBm
*RST:
23 dBm
Default unit: dBm
Example:
See
Firmware/Software:
V3.7.20
Manual operation:
See
SENSe:NIOT:SIGN<i>:UL:ADPower:ENPPpower?
Queries the expected power of the first preamble, resulting from the UL power control
settings.
Return values:
<Power>
Default unit: dBm
Example:
See
Usage:
Query only
Firmware/Software:
V3.7.20
Manual operation:
See
SENSe:NIOT:SIGN<i>:UL:ADPower:EFNPower<format>?
Queries the expected NPUSCH power, for the NPUSCH formats 1 and 2.
Suffix:
<format>
.
1, 2
Return values:
<ExpectedPower>
Default unit: dBm
Example:
See
Usage:
Query only
Firmware/Software:
V3.7.20
Manual operation:
See
"Exp. NPUSCH Format 1/2 Nom. Power"
Command Reference