NB-IoT NPRACH Measurement
R&S
®
CMW-KM300/-KS300
369
User Manual 1178.5689.02 ─ 06
Firmware/Software:
V3.7.20
Manual operation:
See
TRIGger:NIOT:MEAS<i>:PRACh:SLOPe
<Slope>
Qualifies whether the trigger event is generated at the rising or at the falling edge of
the trigger pulse (valid for external and power trigger sources).
Parameters:
<Slope>
REDGe | FEDGe
REDGe:
Rising edge
FEDGe:
Falling edge
*RST:
REDG
Example:
See
Configuring the Trigger System
Firmware/Software:
V3.7.20
Manual operation:
See
TRIGger:NIOT:MEAS<i>:PRACh:THReshold
<TrigThreshold>
Defines the trigger threshold for power trigger sources.
Parameters:
<TrigThreshold>
Range:
-50 dB to 0 dB
*RST:
-20 dB
Default unit: dB (full scale, i.e. relative to reference level minus
external attenuation)
Example:
See
Configuring the Trigger System
Firmware/Software:
V3.7.20
Manual operation:
See
TRIGger:NIOT:MEAS<i>:PRACh:TOUT
<TriggerTimeOut>
Selects the maximum time that the measurement waits for a trigger event before it
stops in remote control mode or indicates a trigger timeout in manual operation mode.
This setting has no influence on "Free Run" measurements.
Parameters:
<TriggerTimeOut>
Range:
0.01 s to 167772.15 s
*RST:
0.1 s
Default unit: s
Additional parameters: OFF | ON (disables | enables the time-
out)
Example:
See
Configuring the Trigger System
Firmware/Software:
V3.7.20
Command Reference