NB-IoT Signaling
R&S
®
CMW-KM300/-KS300
192
User Manual 1178.5689.02 ─ 06
2.5.15.3
Measurement Results
The following commands retrieve the results of the BLER measurement.
FETCh:NIOT:SIGN<i>:BLER:ABSolute?
...........................................................................192
FETCh:NIOT:SIGN<i>:BLER:RELative?
........................................................................... 192
FETCh:NIOT:SIGN<i>:BLER:UL:ABSolute?
......................................................................193
FETCh:NIOT:SIGN<i>:BLER:UL:RELative?
...................................................................... 193
FETCh:NIOT:SIGN<i>:BLER:ABSolute?
Returns the absolute results of the BLER measurement.
Return values:
<Reliability>
See
<ACK>
Number of received acknowledgments
<NACK>
Number of received negative acknowledgments
<Samples>
Number of already processed DL transmissions
<Throughput>
Two comma-separated values: average throughput and maxi-
mum reachable throughput
Default unit: bit/s
<DTX>
Number of sent scheduled subframes for which no ACK and no
NACK has been received
Example:
See
Configuring a BLER Measurement
Usage:
Query only
Firmware/Software:
V3.7.20
Manual operation:
See
FETCh:NIOT:SIGN<i>:BLER:RELative?
Returns the relative results of the BLER measurement.
Return values:
<Reliability>
See
<ACK>
Received acknowledgments (percentage of sent scheduled sub-
frames)
Range:
0 % to 100 %
Default unit: %
<NACK>
Received negative acknowledgments (percentage of sent
scheduled subframes)
Range:
0 % to 100 %
Default unit: %