NB-IoT Signaling
R&S
®
CMW-KM300/-KS300
104
User Manual 1178.5689.02 ─ 06
CONFigure:NIOT:SIGN:SMS:OUTGoing:FILE:INFO?
// *****************************************************************************
// Get information about an old received short message:
// Select a message file and query information about it.
// *****************************************************************************
CONFigure:NIOT:SIGN:SMS:INComing:FILE "@USERDATA\sms\NBIOT\Received\rx_001.sms"
CONFigure:NIOT:SIGN:SMS:INComing:FILE:INFO?
2.4.2
BLER Tests
The BLER measurement provided by the NB-IoT signaling application is programmed
as follows:
●
The application is controlled by SCPI commands with the following syn-
tax:
...:NIOT:SIGN:BLER:...
●
After a
*RST
, the measurement is switched off.
You can start the measurement using
INIT:NIOT:SIGN:BLER
and retrieve the
results using
FETCh
commands.
The examples in this section focus on commands directly related to the BLER mea-
surement. For general configuration of the signaling application and setting up the con-
nection, refer to
Chapter 2.4.1, "General Configuration"
2.4.2.1
Configuring a BLER Measurement
// *****************************************************************************
// Configure a BLER measurement with 1000 transmissions.
// NACK and DTX contribute to the BLER.
// *****************************************************************************
CONFigure:NIOT:SIGN:BLER:SAMPles 1000
CONFigure:NIOT:SIGN:BLER:ERCalc ERC1
2.4.2.2
Running a BLER Measurement
// *****************************************************************************
// Start the BLER measurement. Wait until the measurement is running.
// *****************************************************************************
INITiate:NIOT:SIGN:BLER
WHILE FETCh:NIOT:SIGN:BLER:STATe:ALL? <> "RUN","ADJ","ACT"
// *****************************************************************************
// Query the measurement results.
// *****************************************************************************
FETCh:NIOT:SIGN:BLER:ABSolute?
FETCh:NIOT:SIGN:BLER:RELative?
FETCh:NIOT:SIGN:BLER:UL:ABSolute?
FETCh:NIOT:SIGN:BLER:UL:RELative?
Programming