NB-IoT Multi-Evaluation Measurement
R&S
®
CMW-KM300/-KS300
318
User Manual 1178.5689.02 ─ 06
FETCh:NIOT:MEAS<i>:MEValuation:LIST:SEGMent<no>:MODulation:EXTReme?
Returns extreme modulation single value results for segment <no> in list mode.
Suffix:
<no>
.
1..1000
Return values:
<1_Reliability>
<2_SegReliability>
Reliability indicator for the segment
<3_StatistExpired>
Reached statistical length in slots
<4_OutOfTol>
Percentage of measured slots with failed limit check
Default unit: %
<5_EVM_RMS>
Error vector magnitude RMS value
Default unit: %
<6_EVMpeak>
Error vector magnitude peak value
Default unit: %
<7_MagErrorRMS>
Magnitude error RMS value
Default unit: %
<8_MagErrPeak>
Magnitude error peak value
Default unit: %
<9_PhErrorRMS>
Phase error RMS value
Default unit: deg
<10_PhErrorPeak>
Phase error peak value
Default unit: deg
<11_IQOffset>
I/Q origin offset
Default unit: dBc
<12_FreqError>
Carrier frequency error
Default unit: Hz
<13_TimingError>
Transmit time error
Default unit: Ts
<14_TXpowerMin>
Minimum user equipment power
Default unit: dBm
<15_TXpowerMax>
Maximum user equipment power
Default unit: dBm
<16_PeakPowerMin> Minimum user equipment peak power
Default unit: dBm
<17_PeakPowerMax>Maximum user equipment peak power
Default unit: dBm
Command Reference
深圳德标仪器
135-1095-0799