NB-IoT Signaling
R&S
®
CMW-KM300/-KS300
77
User Manual 1178.5689.02 ─ 06
Remote command:
CONFigure:NIOT:SIGN<i>:CONNection:RMC:DL
Repetitions
Selects the number of NPDSCH repetitions.
Remote command:
CONFigure:NIOT:SIGN<i>:CONNection:RMC:DL
2.3.11.4
User-Defined Scheduling Settings
Access: "Config" hotkey > "Connection" > "User-Defined Scheduling" section.
The parameters in this section apply if
The UL settings are used for NPUSCH format 1. The settings for NPUSCH format 2
are fixed.
There are dependencies between the settings. Configure the UL or DL settings from
the top left to the bottom.
For valid parameter combinations, see
Chapter 2.2.10, "User-Defined Scheduling"
Figure 2-46: Settings for user-defined scheduling
.........................................................................................78
.......................................................................................... 78
Pattern
The signaling application sends a UL grant or a DL grant to the UE at each possible
search space occasion.
The pattern defines the sequence of the grants.
"Alternating
DL/UL"
Alternating DL grants and UL grants are sent. The provided data rate
is 3.2
kbps on DL and 150
This scheduling can be used for end-to-end data connections.