// segment length 6 slots, power 3 dBm, frequency 1.95 GHz
// *****************************************************************************
CONF:NIOT:MEAS:MEV:LIST:SEGM2:SET 6,3,OB1,1.95E+9,F1,12,0,NRU01,NR2,IFPower,0
// *****************************************************************************
// Enable modulation results except phase error for both segments.
// Set statistical length to entire NPUSCH duration.
// *****************************************************************************
CONF:NIOT:MEAS:MEValuation:LIST:SEGMent1:MODulation 16,ON,ON,ON,OFF,ON,QPSK
CONF:NIOT:MEAS:MEValuation:LIST:SEGMent2:MODulation 4,ON,ON,ON,OFF,ON,QPSK
// *****************************************************************************
// Enable all spectrum emission results for segment 2.
// Enable the GSM ACLR results for segment 2 (no UTRA results).
// Set statistical length to entire NPUSCH duration.
// *****************************************************************************
CONFigure:NIOT:MEAS:MEValuation:LIST:SEGMent2:SEMask 4,ON
CONFigure:NIOT:MEAS:MEValuation:LIST:SEGMent2:ACLR 4,ON,OFF,ON
// *****************************************************************************
// Select both segments for measurement and evaluate retrigger flags.
// *****************************************************************************
CONFigure:NIOT:MEAS:MEValuation:LIST:LRANge 1,2
TRIGger:NIOT:MEAS:MEValuation:LIST:MODE SEGMent
// *****************************************************************************
// Only for measurements with R&S CMWS:
// Configure the RF input connector per segment.
// *****************************************************************************
CONFigure:NIOT:MEAS:MEValuation:LIST:CMWS:CMODe LIST
CONFigure:NIOT:MEAS:MEValuation:LIST:SEGMent1:CMWS:CONNector R11
CONFigure:NIOT:MEAS:MEValuation:LIST:SEGMent2:CMWS:CONNector R12
// *****************************************************************************
// Enable the list mode.
// *****************************************************************************
CONFigure:NIOT:MEAS:MEValuation:LIST ON
3.4.2.3
Performing Single-Shot Measurements
// *****************************************************************************
// Start single-shot measurement.
// Return the individual segment reliability indicators.
// *****************************************************************************
INIT:NIOT:MEAS:MEValuation
FETCh:NIOT:MEAS:MEValuation:LIST:SRELiability?
// *****************************************************************************
// Return average and extreme modulation results.