NB-IoT Signaling
R&S
®
CMW-KM300/-KS300
40
User Manual 1178.5689.02 ─ 06
Remote command:
SENSe:NIOT:SIGN<i>:UECapability:MAC:RELassind?
Physical Layer UE Capabilities
This section indicates physical layer capabilities of the UE.
Figure 2-16: Physical layer UE capabilities
.......................................................................................... 40
Multi-Tone
Indicates whether the UE supports NPUSCH multi-tone transmissions.
This information is received in the information element "UE-Capability-NB".
Remote command:
SENSe:NIOT:SIGN<i>:UECapability:TRANsfer:PHYSical:MTONe?
Multi-Carrier
Indicates whether the UE supports multi-carrier operation.
This information is received in the information element "UE-Capability-NB".
Remote command:
SENSe:NIOT:SIGN<i>:UECapability:TRANsfer:PHYSical:MCARrier?
Multi-Carrier NPRACH
Indicates whether the UE supports NPRACH on non-anchor carrier, as specified in
3GPP TS 36.321 and 36.331.
Remote command:
SENSe:NIOT:SIGN<i>:UECapability:TRANsfer:PHYSical:MCRRier:
NPRach?
Two HARQ Processes
Indicates whether the UE supports two HARQ processes in DL and UL.
Remote command:
SENSe:NIOT:SIGN<i>:UECapability:TRANsfer:PHYSical:TWOHarq?
Interference Randomization
Indicates whether the UE supports interference randomization in connected mode as
specified in 3GPP TS 36.211.
GUI Reference
深圳德标仪器
135-1095-0799