NB-IoT Signaling
R&S
®
CMW-KM300/-KS300
171
User Manual 1178.5689.02 ─ 06
Parameters:
<Subcarriers>
SC12 | KEEP
Number of subcarriers (only in the query form of the command)
This parameter is not editable, for the setting, use value "KEEP".
*RST:
SC12
<StartSubcarrier>
0 | KEEP
Start subcarrier (only in the query form of the command)
This parameter is not editable, for the setting, use value "KEEP".
*RST:
0
<MCSindex>
MI6
MCS index value
*RST:
MI6
<Subframes>
NSF01
Number of subframes
*RST:
NSF01
<Repetitions>
NR1
Number of NPDSCH repetitions
*RST:
NR1
Example:
See
Firmware/Software:
V3.7.20
Manual operation:
See
"Subcarriers, Start Subcarrier"
CONFigure:NIOT:SIGN<i>:CONNection:RMC:DL:MCSindex?
Queries the configured MCS index and the resulting modulation scheme and transport
block size for the scheduling type DL RMC, see
Chapter 2.2.9, "Scheduling Type DL
Return values:
<MCSindex>
MI6
MCS index value
<Modulation>
QPSK
Modulation scheme
<TransBlockSize>
Transport block size
Example:
See
Usage:
Query only
Firmware/Software:
V3.7.20
Manual operation:
See
Command Reference