NB-IoT Signaling
R&S
®
CMW-KM300/-KS300
79
User Manual 1178.5689.02 ─ 06
2.3.11.5
HARQ Settings
Access: "Config" hotkey > "Connection" > "HARQ" section.
The following parameters configure the HARQ procedure for downlink and uplink trans-
missions.
Figure 2-47: Settings for HARQ procedure
............................................................................................... 79
............................................................................................79
HARQ
Enables or disables hybrid automatic repeat request (HARQ).
Remote command:
CONFigure:NIOT:SIGN<i>:CONNection:HARQen
No. of HARQ Processes
Specifies the number of HARQ processes.
Remote command:
CONFigure:NIOT:SIGN<i>:CONNection:NUMHqpc
Max. No. of Transmissions
Specifies the maximum number of transmissions, including initial transmissions and
retransmissions.
Remote command:
CONFigure:NIOT:SIGN<i>:CONNection:MAXNumtr
2.3.11.6
NPDCCH Settings
Access: "Config" hotkey > "Connection" > "NPDCCH" section.
The following parameters configure narrowband physical downlink control channel
(NPDCCH) as defined in 3GPP TS 36.213.
For overview of physical DL channels description, refer to
Figure 2-48: NPDCCH settings
GUI Reference
深圳德标仪器
135-1095-0799