CONFigure:NIOT:SIGN<i>:FADing:FSIMulator:RESTart
..................................................... 136
CONFigure:NIOT:SIGN<i>:FADing:FSIMulator:RESTart:MODE
.......................................... 137
SENSe:NIOT:SIGN<i>:FADing:FSIMulator:ILOSs:CSAMples<ClippingCounter>?
CONFigure:NIOT:SIGN<i>:FADing:FSIMulator:DSHift
<Frequency>
Sets the maximum Doppler frequency for the fading simulator.
A setting is only allowed in
USER
CONFigure:NIOT:SIGN<i>:FADing:
).
Parameters:
<Frequency>
Range:
1 Hz to 2000 Hz
*RST:
5 Hz
Default unit: Hz
Example:
See
Firmware/Software:
V3.7.60
Options:
R&S CMW-KE100 and -KE500
Manual operation:
See
"Doppler Frequency Mode, Doppler Frequency"
CONFigure:NIOT:SIGN<i>:FADing:FSIMulator:DSHift:MODE
<Mode>
Sets the Doppler shift mode.
Parameters:
<Mode>
NORMal | USER
NORMal
: The maximum Doppler frequency is determined by the
fading profile.
USER
: The maximum Doppler frequency is configurable.
*RST:
NORM
Example:
See
Firmware/Software:
V3.7.60
Options:
R&S CMW-KE100 and -KE500
Manual operation:
See
"Doppler Frequency Mode, Doppler Frequency"
CONFigure:NIOT:SIGN<i>:FADing:FSIMulator:ENABle
<Enable>
Enables/disables the fading simulator.
Parameters:
<Enable>
OFF | ON
Example:
See
Firmware/Software:
V3.7.60
Options:
R&S CMW-KE100 and -KE500
Command Reference