Fading is started and restarted manually. A "Restart" button is dis-
played.
Remote command:
CONFigure:NIOT:SIGN<i>:FADing:FSIMulator:RESTart:MODE
CONFigure:NIOT:SIGN<i>:FADing:FSIMulator:RESTart
Start Seed
Sets the start seed for the pseudo-random fading algorithm. This setting ensures
reproducible fading conditions.
Remote command:
CONFigure:NIOT:SIGN<i>:FADing:FSIMulator:GLOBal:SEED
Insertion Loss
The insertion loss is the attenuation at the fader input. It can be calculated automati-
cally or you can define it manually.
"Normal"
The insertion loss is calculated automatically, based on the currently
selected
.
"User"
Specify the insertion loss value. A lower insertion loss allows for a
higher downlink power but can result in clipping.
You can use the displayed information "Clipped Samples" to find the
lowest insertion loss value for which no clipping occurs. For scenarios
with several output paths, the information is displayed per path.
Remote command:
CONFigure:NIOT:SIGN<i>:FADing:FSIMulator:ILOSs:MODE
CONFigure:NIOT:SIGN<i>:FADing:FSIMulator:ILOSs:LOSS
SENSe:NIOT:SIGN<i>:FADing:FSIMulator:ILOSs:
CSAMples<ClippingCounter>?
Doppler Frequency Mode, Doppler Frequency
The maximum Doppler frequency can be calculated automatically or you can define it
manually.
"Normal"
The maximum Doppler frequency is calculated automatically, based
on the currently selected
.
"User"
Specify the maximum Doppler frequency.
Remote command:
CONFigure:NIOT:SIGN<i>:FADing:FSIMulator:DSHift:MODE
CONFigure:NIOT:SIGN<i>:FADing:FSIMulator:DSHift
2.3.6.2
DL Settings
Access: "Config" hotkey > "Internal Fading" node > "DL Settings" section.
The node displays noise power values, calculated from the downlink power, the cell
bandwidth and the fading module AWGN settings.
For carrier aggregation scenarios, this information is available per component carrier.
The reference point for the power values is the RF output connector.