NB-IoT Signaling
R&S
®
CMW-KM300/-KS300
135
User Manual 1178.5689.02 ─ 06
Manual operation:
See
CONFigure:NIOT:SIGN<i>:FADing:FSIMulator:GLOBal:SEED
<Seed>
Sets the start seed for the pseudo-random fading algorithm.
Parameters:
<Seed>
Range:
0 to 9
*RST:
0
Example:
See
Firmware/Software:
V3.7.60
Options:
R&S CMW-KE100 and -KE500
Manual operation:
See
CONFigure:NIOT:SIGN<i>:FADing:FSIMulator:ILOSs:LOSS
<InsertionLoss>
Sets the insertion loss for the fading simulator.
A setting is only allowed in
USER
CONFigure:NIOT:SIGN<i>:FADing:
).
Parameters:
<InsertionLoss>
Range:
0 dB to 18 dB
*RST:
0 dB
Default unit: dB
Example:
See
Firmware/Software:
V3.7.60
Options:
R&S CMW-KE100 and -KE500
Manual operation:
See
CONFigure:NIOT:SIGN<i>:FADing:FSIMulator:ILOSs:MODE
<InsertLossMode>
Sets the insertion loss mode.
Parameters:
<InsertLossMode>
NORMal | USER
NORMal
: The insertion loss is determined by the fading profile.
USER
: The insertion loss is configurable.
*RST:
NORM
Example:
See
Firmware/Software:
V3.7.60
Options:
R&S CMW-KE100 and -KE500
Manual operation:
See