CONFigure:NIOT:SIGN<i>:CELL:RESelection:QUALity
<Qqualmin>, <Qrxlevmin>,
<Qhyst>
Defines the power levels required for cell reselection. They are transmitted to the UE in
the system information.
Parameters:
<Qqualmin>
Minimum required quality level in the reselection target cell.
Range:
-34 dB to -3 dB
*RST:
OFF
Additional parameters: OFF | ON (disables | enables transmis-
sion of the information element)
<Qrxlevmin>
Minimum required RX level at a UE antenna for reselection to
the target cell
Range:
-140 dBm to -44 dBm
Increment: 2 dBm
*RST:
-140 dBm
<Qhyst>
Hysteresis
Range:
0 dB to 24 dB
Increment: 1 dB, 2 dB for hysteresis values 6 dB to 24dB
*RST:
0 dB
Example:
See
Configuring Neighbor Cells and Reselection
Firmware/Software:
V3.7.50
Manual operation:
See
CONFigure:NIOT:SIGN<i>:CELL:RESelection:SEARch:INTRasearch
<Sintrasearch>
Defines the threshold S
IntraSearch
. The value divided by 2 is broadcast to the UE in SIB3.
Parameters:
<Sintrasearch>
Range:
0 dB to 62 dB
Increment: 2 dB
*RST:
62 dB
Default unit: dB
Example:
See
Configuring Neighbor Cells and Reselection
Firmware/Software:
V3.7.50
Manual operation:
See
CONFigure:NIOT:SIGN<i>:CELL:RESelection:SEARch:NINTrasearch
<Snonintrasearch>
Defines the threshold S
nonIntraSearch
. The value divided by 2 is broadcast to the UE in