NB-IoT Signaling
R&S
®
CMW-KM300/-KS300
65
User Manual 1178.5689.02 ─ 06
How to configure network for cell reselection is described in
Figure 2-36: Settings for cell reselection
S IntraSearch
Sets the threshold S
IntraSearch
for intra-frequency measurements.
The threshold is configured in dB. System information block 3 contains the configured
value divided by 2.
Remote command:
CONFigure:NIOT:SIGN<i>:CELL:RESelection:SEARch:INTRasearch
S NonIntraSearch
Sets the threshold S
nonIntraSearch
for inter-frequency measurements.
The threshold is configured in dB. System information block 3 contains the configured
value divided by 2.
Remote command:
CONFigure:NIOT:SIGN<i>:CELL:RESelection:SEARch:NINTrasearch
Q qualmin
Sets minimum required quality level in the target cell.
Remote command:
CONFigure:NIOT:SIGN<i>:CELL:RESelection:QUALity
Q Rxlevmin
Sets minimum required received RSRP level in the target cell in dBm (Q
rxlevmin
).
The level is configured in dBm. System information block 1 contains the configured
value divided by 2.
Remote command:
CONFigure:NIOT:SIGN<i>:CELL:RESelection:QUALity
Q Hyst
Sets the hysteresis for the cell reselection algorithm.
GUI Reference