About the local and remote power controls
You can press the
Remote
and
Local
switches on the power control panel to
change power control from local to remote at any time. Local power control means
that you can turn power on and off using the switches on the power control panel.
Remote power control means that you turn power on and off from another source,
as shown in the following table.
Table 8. Remote power control
Element
Remote Power Controlled From:
Printer 2 Control Unit Power
Host System Console
Printer 1 Power
Printer 1 Control Unit
Printer 1 Control Unit Power
Printer 2 Control Unit
Printer 2 Power
Printer 2 Control Unit
Powering on the system
You can switch power on for the complete system for Duplex or for Dual Simplex
mode. Or you can switch power on for only one printer and its associated control
unit in Dual Simplex mode when one of the two system printers cannot be used
and needs repair. In either mode, and with the use of either printer, you must
switch the Printer 2 control unit power on.
The method you use to switch power on for the system depends on whether
power control is set to
Local
or
Remote
. See “About the local and remote power
controls” on page 30 for details.
Note:
1.
The Printer 2 control unit must have power on to switch on power for Printer 1
even if Printer 2 is powered off.
2.
The
Unit Emergency
switch in each printer must be in the
Power Enable
position before you can switch power on to that printer.
3.
If a D208 intervention message occurs after you switch power on for the
system, do the following:
a.
Ensure the printers are powered on.
b.
On the Main touch panel, select
Shutdown
and then
Restart
.
c.
If the error occurs again, switch power off for the system.
d.
Wait two minutes.
e.
Switch power on for the system again.
Note:
If you are operating the system in dual simplex mode and leave one
printer powered-off, the D208 error remains on the powered-off printer panel.
Powering on the system in local-controlled mode
Before you begin
Attention:
You can switch power on for the complete system for duplex or for
dual simplex mode. Or you can switch power on for only one printer and its
associated control unit in dual simplex mode when one of the two system printers
cannot be used and needs repair. In either mode, and with the use of either printer,
you must switch the Printer 2 control unit power on.
48
Operating the InfoPrint 4100
Содержание InfoPrint 4100 TD3
Страница 1: ...Operating the InfoPrint 4100 InfoPrint 4100 Models TS2 TD3 4 TS3 and TD5 6 S550 1298 02...
Страница 2: ......
Страница 3: ...Operating the InfoPrint 4100 InfoPrint 4100 Models TS2 TD3 4 TS3 and TD5 6 S550 1298 02...
Страница 8: ...vi Operating the InfoPrint 4100...
Страница 12: ...x Operating the InfoPrint 4100...
Страница 14: ...xii Operating the InfoPrint 4100...
Страница 60: ...46 Operating the InfoPrint 4100...
Страница 90: ...6 Open the lower tractor covers on the transfer station g5amc377 1 1 2 3 4 76 Operating the InfoPrint 4100...
Страница 97: ...2 Swing the roller 3 into the open position by pressing down on 1 and 2 Chapter 5 Working with forms 83...
Страница 107: ...4 Open the lower tractor covers on the transfer station ic3mc335 2 4 3 1 Chapter 5 Working with forms 93...
Страница 127: ...2 Swing the roller 3 into the open position by pressing down on 1 and 2 Chapter 5 Working with forms 113...
Страница 140: ...2 Swing the roller 3 into the open position by pressing down on 1 and 2 126 Operating the InfoPrint 4100...
Страница 268: ...254 Operating the InfoPrint 4100...
Страница 360: ...346 Operating the InfoPrint 4100...
Страница 407: ...Administrator panel Chapter 8 Help topics for the InfoPrint 4100 operator console 393...
Страница 408: ...394 Operating the InfoPrint 4100...
Страница 461: ......
Страница 462: ...Program Number 5765 G79 5765 G74 Printed in USA S550 1298 02...