Rev. 5.00, 09/03, page 76 of 760
3.5.3
TLB Invalid Exception
A TLB invalid exception results when the virtual address is compared to a selected TLB entry
address array and a match is found but the entry is not valid (the V bit is 0). TLB invalid exception
processing includes both hardware and software operations.
Hardware Operations: In a TLB invalid exception, the SH7709S hardware executes a set of
prescribed operations, as follows:
1. The VPN number of the virtual address causing the exception is written to the PTEH register.
2. The virtual address causing the exception is written to the TEA register.
3. The way number causing the exception is written to RC in MMUCR.
4. Either exception code H'040 for a load access, or H'060 for a store access, is written to the
EXPEVT register.
5. The PC value indicating the address of the instruction in which the exception occurred is
written to the SPC. If the exception occurred in a delay slot, the PC value indicating the
address of the delayed branch instruction is written to the SPC.
6. The contents of SR at the time of the exception are written into SSR.
7. The mode (MD) bit in SR is set to 1 to place the SH7709S in the privileged mode.
8. The block (BL) bit in SR is set to 1 to mask any further exception requests.
9. The register bank (RB) bit in SR is set to 1.
10. Execution branches to the address obtained by adding the value of the VBR contents and
H'00000100, and the TLB protection violation exception handler starts.
Software (TLB Invalid Exception Handler) Operations: The software searches the page tables
in external memory and assigns the required page table entry. Upon retrieving the required page
table entry, software must execute the following operations:
1. Write the values of the physical page number (PPN) field and the values of the protection key
(PR), page size (SZ), cacheable (C), dirty (D), share status (SH), and valid (V) bits of the page
table entry recorded in the external memory to the PTEL register.
2. If using software for way selection for entry replacement, write the desired value to the RC
field in MMUCR.
3. Issue the LDTLB instruction to load the contents of PTEH and PTEL into the TLB.
4. Issue the RTE instruction to terminate the handler and return to the instruction stream. The
RTE instruction should be issued after two LDTLB instructions.
Содержание SH7709S
Страница 2: ......
Страница 44: ...Rev 5 00 09 03 page xliv of xliv ...
Страница 62: ...Rev 5 00 09 03 page 18 of 760 ...
Страница 128: ...Rev 5 00 09 03 page 84 of 760 ...
Страница 146: ...Rev 5 00 09 03 page 102 of 760 ...
Страница 224: ...Rev 5 00 09 03 page 180 of 760 ...
Страница 246: ...Rev 5 00 09 03 page 202 of 760 ...
Страница 266: ...Rev 5 00 09 03 page 222 of 760 ...
Страница 370: ...Rev 5 00 09 03 page 326 of 760 ...
Страница 432: ...Rev 5 00 09 03 page 388 of 760 ...
Страница 532: ...Rev 5 00 09 03 page 488 of 760 ...
Страница 598: ...Rev 5 00 09 03 page 554 of 760 ...
Страница 630: ...Rev 5 00 09 03 page 586 of 760 ...
Страница 656: ...Rev 5 00 09 03 page 612 of 760 ...
Страница 684: ...Rev 5 00 09 03 page 640 of 760 ...
Страница 700: ...Rev 5 00 09 03 page 656 of 760 ...
Страница 758: ...Rev 5 00 09 03 page 714 of 760 ...
Страница 807: ...SH7709S Group Hardware Manual REJ09B0081 0500O ADE 602 250C ...