Rev. 5.00, 09/03, page 155 of 760
Bits 3 and 2—Read/Write Select A (RWA1, RWA0): Selects the read cycle or write cycle as the
bus cycle of the channel A break condition.
Bit 3: RWA1
Bit 2: RWA0
Description
0
0
Condition comparison is not performed
(Initial value)
1
The break condition is the read cycle
1
0
The break condition is the write cycle
1
The break condition is the read cycle or write cycle
Bits 1 and 0—Operand Size Select A (SZA1, SZA0): Selects the operand size of the bus cycle
for the channel A break condition.
Bit 1: SZA1
Bit 0: SZA0
Description
0
0
The break condition does not include operand size
(Initial value)
1
The break condition is byte access
1
0
The break condition is word access
1
The break condition is longword access
Содержание SH7709S
Страница 2: ......
Страница 44: ...Rev 5 00 09 03 page xliv of xliv ...
Страница 62: ...Rev 5 00 09 03 page 18 of 760 ...
Страница 128: ...Rev 5 00 09 03 page 84 of 760 ...
Страница 146: ...Rev 5 00 09 03 page 102 of 760 ...
Страница 224: ...Rev 5 00 09 03 page 180 of 760 ...
Страница 246: ...Rev 5 00 09 03 page 202 of 760 ...
Страница 266: ...Rev 5 00 09 03 page 222 of 760 ...
Страница 370: ...Rev 5 00 09 03 page 326 of 760 ...
Страница 432: ...Rev 5 00 09 03 page 388 of 760 ...
Страница 532: ...Rev 5 00 09 03 page 488 of 760 ...
Страница 598: ...Rev 5 00 09 03 page 554 of 760 ...
Страница 630: ...Rev 5 00 09 03 page 586 of 760 ...
Страница 656: ...Rev 5 00 09 03 page 612 of 760 ...
Страница 684: ...Rev 5 00 09 03 page 640 of 760 ...
Страница 700: ...Rev 5 00 09 03 page 656 of 760 ...
Страница 758: ...Rev 5 00 09 03 page 714 of 760 ...
Страница 807: ...SH7709S Group Hardware Manual REJ09B0081 0500O ADE 602 250C ...