Instruction manual
Page 109 / 189
Copyright © REA Elektronik
REA JET HR
pro
2K / 4K
V 3.5x_001 28.05.2015
4.2 Detailed description of the connections incl. connection
values
4.2.1 Mains connection (A1)
4.2.1.1
Connection for power supply and power switches (A1)
Figure 141: Connection for the power supply (cold device plug) on the front device side
(=A1)
4.2.1.1.1
Assignment of the mains connection (A1)
Table 14: Assignment of the mains connection
(=A1
)
Pin HR
Name
Value
I/O
1
Phase
95V -250V
AC
2
PE protective conductor
3
Neutral conductor
Figure 142: View of the contacts of the
integrated plug
4.2.1.1.2
Power supply values of the REA JET HR
pro
control device
Marking system
REA JET HR
pro
2K REA JET HR
pro
4K
Unit
Name
Value
Value
Tension
95 - 250
95 - 250
V AC
Current
at 115V
max. 1.2
max. 2.4
A
at 230V
max. 0.6
max. 1.2
A
Start-up current
max.
80
80
A
Duration of the start-up current
max.
10
10
ms
Fuse
max.
10
10
A
Characteristic fuse
B (pref. C)
B (pref. C)
Frequency
50 - 60
50 - 60
Hz
The REA JET HR
pro
is equipped with a wide-range
power supply. In the range 95V to 250V AC this
power supply unit adapts automatically to the applied
supply voltage.
This enables the worldwide use of the REA JET HR
pro
with just one device type and without any
conversion work.
REA JET HR
pro
is turned on and off with this
switch.
The mains voltage is double pole isolated with this
switch.
2
3
1