Instruction manual
Page 139 / 189
Copyright © REA Elektronik
REA JET HR
pro
2K / 4K
V 3.5x_001 28.05.2015
No.
Name of element
Function / description
1
Plug
(in circuit board assembly)
For the connection of the I/O connection of the REA JET HR
pro
2K/4K
2
Pin header
For the connection of a cable with panel plug (054.880.103).
Enables the installation of the connection plug directly in the
control cabinet wall.
3
Safety fuse
To secure the connecting element
Value of the fuse 2A medium time lag;
Dimensions: 5 x 20mm
4
Label holder
For the norm-compliant marking of the REA JET connecting
element.
5
Status-LED
for the inputs
6 green LEDs
for the display of the inputs of REA JET HR
pro
2K/4K
6
Status-LED
for the outputs
4 green LEDs
for the display of the status of the outputs of REA JET HR
pro
2K/4K
7
Output terminal block
Terminal block for 4 outputs.
In addition to each output clamp, one clamp for UB+ and mass.
8
Input terminal block
Terminal block for 6 inputs.
In addition to each input clamp, one clamp for UB+ and mass.
9
Terminal block for external
supply voltage
UB+ and mass connection for the supply of REA JET HR
pro
2K/4K internal I/O circuit.*
(double terminals for simple wiring)
10
Terminal block for the voltage
-
of the
REA JET HR
pro
2K/4K
internal power supply
UB+ and mass connection of the REA JET HR
pro
2K/4K power
supply.*
(double terminals for simple wiring)
11
Socket
(circuit board mounting)
For the connection of further I/O components.
The signals of the connection plug
(1)
are connected at this
socket 1:1.
12
Functional earth
6.3mm Faston connection for functional earth.
13
Status
– LED
HR internal power supply
green LED
to display the voltage of the REA JET HR
pro
2K/4K internal
power supply
14
Status
– LED
voltage supply of HR internal
I/O circuit
green LED
for the display of the voltage for the supply of REA JET HR
pro
2K/4K internal I/O circuit.
15
Pin header
For the connection of a cable with panel socket (054.880.104).
Enables the installation of the connection socket directly in the
control cabinet wall.
*) Please observe the information on the internal and external supply of REA JET HR
pro
2K/4K internal I/O circuits at
4.2.12.1.3 on page 4.2.12.1.3.
Table 37: Elements of the REA JET connecting element.