4.2.22.2 Elements of the I/O multiplier
The I/O multiplier has the following connections and displays:
Figure 204: Elements of the I/O multiplier
No.
Name of element
Function / description
1
I/O panel plug
Connection "
REA JET HR
" to connect with the I/O connection of
a REA JET HR
pro
2K/4K control device
2
Safety fuse
Securing the supply voltage of the REA JET HR
pro
2K/4K
internal I/O circuit.
Value of the fuse 2A medium time lag; size: 5 x 20mm
3
Status
– LED
voltage supply of HR internal
I/O circuit
green LED
for the display of the voltage for the supply of REA JET HR
pro
2K/4K internal I/O circuit (e.g. by an external source).
4
Status
– LED
HR internal power supply
green LED
to display the voltage of the REA JET HR
pro
2K/4K internal
power supply
5
I/O panel socket 3
I/O connection no. 3
– "
Signal Tower
"
Intended for one signal lamp.
6
I/O panel socket 2
I/O connection no. 2
– "
Signal Tower
"
Intended for one signal lamp.
7
I/O panel socket 1
I/O connection no. 1
– "
SPS
"
Intended for an external SPS (incl. external power supply
8
Ground bolts M5
Connection for functional earth or to connect the cable shields of
the I/O cable.
Table 40: Elements of the I/O multiplier
4.2.22.3 Assignment of the I/O plug connector of the I/O multiplier
Identical to the I/O connection of REA JET HR
pro
2K/4K. See under 4.2.12.1.1 on page 118.
4.2.22.4 Electrical limit values of the I/O multiplier
Identical to those of the I/O connection of REA JET HR
pro
2K/4K. See under 4.2.12.1.2 on page